# 🔌 Server connectivity — síťová a storage konektivita
|
|
||||||
|
|
||||||
## Ethernet — síťová konektivita
|
|
||||||
|
|
||||||
### Rychlosti a formáty
|
|
||||||
|
|
||||||
| Rychlost | Označení | Form factor | Kabeláž | Rok standardu | Use case |
|
|
||||||
|----------|----------|-------------|---------|---------------|----------|
|
|
||||||
| **1 GbE** | 1000BASE-T | RJ45 (copper) | Cat5e/Cat6 | 1999 | Management, legacy |
|
|
||||||
| **10 GbE** | 10GBASE-T / SFP+ | RJ45 / SFP+ | Cat6A (30m) / Cat7 (100m) / DAC / SR/LR | 2006 | Běžný server, storage |
|
|
||||||
| **25 GbE** | 25GBASE-R | SFP28 | Cat8 (30m) / DAC (5m) / SR/LR (100m/10km) | 2016 | Standard pro servery (2020+) |
|
|
||||||
| **40 GbE** | 40GBASE-R | QSFP+ | DAC (7m) / SR (150m) / LR (10km) | 2010 | Legacy, spine |
|
|
||||||
| **50 GbE** | 50GBASE-R | SFP56 | DAC / SR / LR | 2018 | Emerging server |
|
|
||||||
| **100 GbE** | 100GBASE-R | QSFP28 | DAC (3m) / SR4 (100m) / LR4 (10km) / PSM4 (500m) | 2015 | Spine, storage, AI |
|
|
||||||
| **200 GbE** | 200GBASE-R | QSFP56 | DAC / SR4 / DR4 | 2019 | AI/ML, HPC |
|
|
||||||
| **400 GbE** | 400GBASE-R | QSFP-DD / OSFP | DAC (2.5m) / SR8 (100m) / DR4 (500m) / FR4 (2km) | 2017 | AI training, hyperscale |
|
|
||||||
| **800 GbE** | 800GBASE-R | QSFP-DD800 / OSFP | DAC (2m) / SR8 (100m) / DR8 (500m) | 2024 | Next-gen AI/ML |
|
|
||||||
|
|
||||||
**Doporučení pro servery (2026)**:
|
|
||||||
- **Standard**: 2× 25 GbE (management + data) nebo 2× 100 GbE pro náročné workloady
|
|
||||||
- **AI/ML training**: 8× 400 GbE (InfiniBand preferován pro GPU communication)
|
|
||||||
- **Storage**: 2× 25/100 GbE (iSCSI/NFS) nebo dedikovaná FC (16/32 Gbps)
|
|
||||||
|
|
||||||
### Form factor NIC
|
|
||||||
|
|
||||||
| Form factor | PCIe lanes | Rychlost | Use case |
|
|
||||||
|------------|-----------|----------|----------|
|
|
||||||
| **OCP 3.0** | x8/x16 | 25/100/200 GbE | Moderní servery (Dell, HPE), small form factor |
|
|
||||||
| **PCIe HHHL** | x8 | 25/50 GbE | Standardní 1U/2U servery |
|
|
||||||
| **PCIe FHHL** | x16 | 100/200/400 GbE | GPU servery, high-density |
|
|
||||||
| **Mezzanine** | x8 | 10/25 GbE | Blade servery (HPE Synergy, Dell MX) |
|
|
||||||
| **LOM (LAN on Motherboard)** | — | 1/10/25 GbE | Integrovaný, základní konektivita |
|
|
||||||
|
|
||||||
### NIC features
|
|
||||||
|
|
||||||
| Feature | Popis | Benefit |
|
|
||||||
|---------|-------|---------|
|
|
||||||
| **TSO/GRO** | TCP Segmentation Offload / Generic Receive Offload | Snížení CPU zátěže pro TCP |
|
|
||||||
| **LRO/LSO** | Large Receive/Send Offload | Obdoba TSO/GRO pro legacy |
|
|
||||||
| **RSS** | Receive Side Scaling | Distribuce příchozích packetů přes více CPU jader |
|
|
||||||
| **RPS/RFS** | Receive Packet Steering / Flow Steering | Softwarové RSS, cache affinity |
|
|
||||||
| **XDP** | eXpress Data Path | BPF-based packet processing (DDoS, load balancer) |
|
|
||||||
| **RDMA (RoCE v2)** | RDMA over Converged Ethernet | GPU direct communication, storage (NVMe-oF) |
|
|
||||||
| **iWARP** | RDMA over TCP | RDMA bez speciálního switch (vyšší latence) |
|
|
||||||
| **DPDK** | Data Plane Development Kit | Uživatelský prostor pro packet processing (VNF, vSwitch) |
|
|
||||||
| **VXLAN/NVGRE offload** | HW offload pro tunelování | Overlay networking (VMware NSX, OpenStack) |
|
|
||||||
| **SR-IOV** | Single Root I/O Virtualization | Direct NIC access pro VM (VF), nízká latence |
|
|
||||||
| **Flow Bifurcation** | Split NIC traffic mezi kernel a DPDK | Souběžný management a high-speed data path |
|
|
||||||
| **PTP (IEEE 1588)** | Precision Time Protocol | Finanční služby, 5G, telco |
|
|
||||||
|
|
||||||
### NIC selection per workload
|
|
||||||
|
|
||||||
| Workload | Doporučená NIC | Zdůvodnění |
|
|
||||||
|----------|---------------|------------|
|
|
||||||
| **Web / API servery** | 2× 25 GbE SFP28, OCP | Nízká cena, dostatečná bandwidth |
|
|
||||||
| **Virtualizace (VMware)** | 2× 25 GbE (SR-IOV, VXLAN offload) | SR-IOV pro VM, VXLAN pro NSX |
|
|
||||||
| **Databáze (OLTP)** | 2× 25/100 GbE (RSS, low latency) | Nízká latence, RSS pro CPU scaling |
|
|
||||||
| **Storage (NFS/iSCSI)** | 2× 25/100 GbE (RoCE v2) | RDMA pro NVMe-oF, low latency |
|
|
||||||
| **Storage (FC SAN)** | 2× 32 Gb FC HBA | SAN pro VMware VMFS, block storage |
|
|
||||||
| **AI/ML training** | 8× 400 GbE + InfiniBand NDR | GPU communication, data ingestion |
|
|
||||||
| **AI/ML inference** | 4× 100 GbE (RoCE v2) | Model serving, GPU direct |
|
|
||||||
| **HPC** | InfiniBand NDR 400 Gbps | MPI communication, low latency |
|
|
||||||
| **Telco / Edge** | 2× 25 GbE (DPDK, PTP) | VNF, 5G UPF, low latency |
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## Storage connectivity
|
|
||||||
|
|
||||||
### Fibre Channel (FC) SAN
|
|
||||||
|
|
||||||
| Generace | Rychlost | Označení | Form factor | Dosah (SMF) | Use case |
|
|
||||||
|----------|----------|----------|-------------|-------------|----------|
|
|
||||||
| **Gen 5** | 16 Gbps | 16GFC | SFP+ | 10 km | Legacy SAN |
|
|
||||||
| **Gen 6** | 32 Gbps | 32GFC | SFP28 | 10 km | Současný standard |
|
|
||||||
| **Gen 7** | 64 Gbps | 64GFC | SFP56 | 10 km | Emerging, high-performance |
|
|
||||||
| **Gen 8** | 128 Gbps | 128GFC | QSFP28 | 10 km | Emerging (první produkční nasazení) |
|
|
||||||
|
|
||||||
**HBA (Host Bus Adapter)**:
|
|
||||||
|
|
||||||
| Výrobce | Model | Rychlost | PCIe | Porty | Features |
|
|
||||||
|---------|-------|----------|------|-------|----------|
|
|
||||||
| **Broadcom / Emulex** | LPe35000 | 32 GFC | PCIe 3.0 x8 | 1-2 | NVMe-FC, T10-PI, SR-IOV |
|
|
||||||
| **Broadcom / Emulex** | LPe36000 | 64 GFC | PCIe 4.0 x16 | 1-2 | NVMe-FC, FC-NVMe |
|
|
||||||
| **Marvell / QLogic** | QLE2770 | 32 GFC | PCIe 3.0 x8 | 1-2 | FC-NVMe, T10-PI |
|
|
||||||
| **Marvell / QLogic** | QLE2870 | 64 GFC | PCIe 4.0 x8 | 1-2 | NVMe-FC, 64GFC |
|
|
||||||
|
|
||||||
**FC SAN topology**:
|
|
||||||
|
|
||||||
```
|
|
||||||
Server ──HBA── FC Switch ──── Storage Array (FC port)
|
|
||||||
│ │
|
|
||||||
│ ┌────┴────┐
|
|
||||||
│ │ Fabric │
|
|
||||||
│ └─────────┘
|
|
||||||
│
|
|
||||||
──── ISL (Inter-Switch Link) ──── backup fabric (B)
|
|
||||||
```
|
|
||||||
|
|
||||||
**Zoning** (FC):
|
|
||||||
|
|
||||||
```
|
|
||||||
Zone A: Server1_HBA1 + Storage_Port1 (production)
|
|
||||||
Zone B: Server1_HBA2 + Storage_Port2 (backup fabric)
|
|
||||||
Zone C: Backup_Server + Storage_Target (backup)
|
|
||||||
```
|
|
||||||
|
|
||||||
### iSCSI
|
|
||||||
|
|
||||||
| Vlastnost | iSCSI | Poznámka |
|
|
||||||
|-----------|-------|----------|
|
|
||||||
| **Transport** | TCP/IP (port 3260) | Po standardním ethernetu |
|
|
||||||
| **Rychlost** | 1/10/25/100 GbE | Stejná jako Ethernet |
|
|
||||||
| **Initiator** | SW (OS) nebo HW (TOE) | SW initiator zdarma, ~5-10 % CPU load |
|
|
||||||
| **Multipathing** | MPIO (Multiple Connections per Session) | Až 8 cest, active/active nebo active/passive |
|
|
||||||
| **CHAP** | Authentication | Mutual CHAP doporučen |
|
|
||||||
| **Jumbo frames** | Doporučeno MTU 9000 | Snížení CPU overhead, vyšší throughput |
|
|
||||||
| **Use case** | Malé a střední SAN, backup, DR | Levnější než FC, nižší výkon |
|
|
||||||
|
|
||||||
**iSCSI configuration**:
|
|
||||||
|
|
||||||
```
|
|
||||||
# Software initiator (Linux)
|
|
||||||
iscsiadm -m discovery -t sendtargets -p 10.0.0.100:3260
|
|
||||||
iscsiadm -m node --login -T iqn.2024-05.storage:array01
|
|
||||||
|
|
||||||
# Multipath (dm-multipath)
|
|
||||||
mpathconf --enable --with_multipathd y
|
|
||||||
# /etc/multipath.conf: aliases, failback, rr_min_io
|
|
||||||
```
|
|
||||||
|
|
||||||
### NVMe-oF (NVMe over Fabrics)
|
|
||||||
|
|
||||||
| Transport | Protokol | Latence | CPU overhead | Use case |
|
|
||||||
|-----------|----------|---------|-------------|----------|
|
|
||||||
| **NVMe over FC** | FC-NVMe (FC Gen 6/7) | <10 µs | Nízký | Enterprise SAN, VMware |
|
|
||||||
| **NVMe over RDMA (RoCE v2)** | RDMA (RoCE) | <5 µs | Velmi nízký | AI/ML, HPC, K8s (CSI) |
|
|
||||||
| **NVMe over TCP** | TCP | ~50 µs | Střední (10-20 % CPU) | Standardní Ethernet, bez RDMA |
|
|
||||||
| **NVMe over InfiniBand** | IB RC/UC | <3 µs | Nejnižší | HPC, AI training |
|
|
||||||
|
|
||||||
**NVMe-oF comparison**:
|
|
||||||
|
|
||||||
| Vlastnost | FC-NVMe | NVMe/RoCE | NVMe/TCP | NVMe/IB |
|
|
||||||
|-----------|---------|-----------|----------|---------|
|
|
||||||
| **Latence (target)** | ~8 µs | ~4 µs | ~50 µs | ~3 µs |
|
|
||||||
| **Bandwidth** | 64 Gbps | 100/200 GbE | 25/100 GbE | NDR 400 Gbps |
|
|
||||||
| **Requires special HW** | FC HBA + switch | RoCE NIC + DCB switch | Standard NIC | IB HCA + switch |
|
|
||||||
| **Ecosystem** | Broadcom, Marvell | NVIDIA, Broadcom | OS built-in | NVIDIA Mellanox |
|
|
||||||
| **Use case** | VMware, enterprise SAN | AI/ML, K8s, HPC | SMB, K8s, cost-effective | HPC, large AI |
|
|
||||||
|
|
||||||
### SAS (Serial Attached SCSI)
|
|
||||||
|
|
||||||
| Generace | Rychlost | Kabeláž | Dosah | Use case |
|
|
||||||
|----------|----------|---------|-------|----------|
|
|
||||||
| **SAS 3** | 12 Gbps | SAS cable (SFF-8644) | 6-10 m | Legacy storage, DAS |
|
|
||||||
| **SAS 4** | 22.5 Gbps | SAS cable (SFF-8644) | 6-10 m | Současný standard |
|
|
||||||
| **SAS 5** | 45 Gbps | SAS cable (SFF-8644) | 6-10 m | Emerging |
|
|
||||||
|
|
||||||
**SAS topology**: Server → SAS HBA → SAS expander → SAS disk (point-to-point, ne shared jako FC)
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## Server connectivity — decision matrix
|
|
||||||
|
|
||||||
| Workload | Primární | Sekundární | Management |
|
|
||||||
|----------|----------|-----------|------------|
|
|
||||||
| **Web / API** | 2× 25 GbE (LACP) | — | 1× 1 GbE BMC |
|
|
||||||
| **Databáze** | 2× 25/100 GbE (RSS) | 2× 32 Gb FC (SAN) | 1× 1 GbE BMC |
|
|
||||||
| **Virtualizace** | 4× 25 GbE (SR-IOV) | 2× 32 Gb FC (VMFS) | 1× 1 GbE BMC |
|
|
||||||
| **Kubernetes** | 2× 25/100 GbE | — | 1× 1 GbE BMC |
|
|
||||||
| **Storage node** | 2× 100 GbE (RoCE) | 2× 25 GbE (management) | 1× 1 GbE BMC |
|
|
||||||
| **AI training** | 8× 400 GbE + IB NDR | 4× 100 GbE (storage) | 1× 1 GbE BMC |
|
|
||||||
| **AI inference** | 4× 100 GbE (RoCE) | 2× 25 GbE (management) | 1× 1 GbE BMC |
|
|
||||||
| **HPC** | InfiniBand NDR | 2× 100 GbE (storage) | 1× 1 GbE BMC |
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## Server NIC placement (PCIe slot optimization)
|
|
||||||
|
|
||||||
```
|
|
||||||
2U Server (GPU/AI):
|
|
||||||
┌─────────────────────────────────────────────────┐
|
|
||||||
│ PCIe 0: GPU (x16) — NVLink / InfiniBand (x16) │
|
|
||||||
│ PCIe 1: GPU (x16) — NIC 100 GbE (x16) │
|
|
||||||
│ PCIe 2: GPU (x16) │
|
|
||||||
│ PCIe 3: GPU (x16) │
|
|
||||||
│ PCIe 4: GPU (x16) │
|
|
||||||
│ PCIe 5: GPU (x16) — NIC 100 GbE (x16) │
|
|
||||||
│ PCIe 6: Storage HBA / NIC (x8) │
|
|
||||||
│ PCIe 7: Management / OCP (x8) │
|
|
||||||
└─────────────────────────────────────────────────┘
|
|
||||||
|
|
||||||
1U Standard:
|
|
||||||
┌─────────────────────────────────┐
|
|
||||||
│ OCP: 2× 25 GbE (management) │
|
|
||||||
│ PCIe 0: NIC 25 GbE (x8) │
|
|
||||||
│ PCIe 1: Storage HBA / FC (x8) │
|
|
||||||
│ PCIe 2: GPU (x16, optional) │
|
|
||||||
│ PCIe 3: NVMe (x4, M.2) │
|
|
||||||
└─────────────────────────────────┘
|
|
||||||
```
|
|
||||||
|
|
||||||
### NVIDIA Mellanox ConnectX NICs
|
|
||||||
|
|
||||||
NVIDIA Mellanox je přední výrobce NIC adaptérů pro AI/HPC a cloud datová centra.
|
|
||||||
|
|
||||||
| Model | PCIe | Max rychlost | Form factor | Klíčové features |
|
|
||||||
|-------|------|-------------|-------------|------------------|
|
|
||||||
| **ConnectX-5** | PCIe 3.0 x16 | 100 GbE (dual) | HHHL | RoCE, NVMe-oF target offload, MPI offload |
|
|
||||||
| **ConnectX-6 Dx** | PCIe 4.0 x16 | 200 GbE (1-port) / 100 GbE (2-port) | HHHL, OCP 3.0 | ASAP² vSwitch offload, IPsec/TLS inline crypto, AES-XTS, 215 Mpps DPDK |
|
|
||||||
| **ConnectX-6 Lx** | PCIe 4.0 x8 | 25 GbE (dual) | HHHL, OCP 3.0 | RoCE, Secure Boot, low-power |
|
|
||||||
| **ConnectX-7** | PCIe 5.0 x16 | 400 GbE (1-port) / 200 GbE (2-port) | HHHL | NDR InfiniBand + 400GbE, GPUDirect, SHARP |
|
|
||||||
| **ConnectX-8** | PCIe 6.0 x16 | 800 GbE (1-port) / 400 GbE (2-port) | HHHL | XDR InfiniBand, sub-500ns latence, in-network computing, multi-host |
|
|
||||||
|
|
||||||
**Platformy**: Spectrum-X Ethernet (end-to-end AI networking), Quantum InfiniBand, BlueField DPU.
|
|
||||||
|
|
||||||
### Broadcom Emulex FC HBA
|
|
||||||
|
|
||||||
| Model | Rychlost | PCIe | Porty | Features |
|
|
||||||
|-------|----------|------|-------|----------|
|
|
||||||
| **LPe35000** (Gen 7) | 32 GFC | PCIe 3.0 x8 | 1-2 | NVMe-FC, T10-PI (DIF), SR-IOV, Silicon Root of Trust |
|
|
||||||
| **LPe35002** (Gen 7) | 32 GFC | PCIe 3.0 x8 | 2 | NVMe-FC, Secure Boot, digitálně podepsaný firmware |
|
|
||||||
| **LPe36000** (Gen 7) | 64 GFC | PCIe 4.0 x16 | 1-2 | První 64GFC HBA na trhu, 10M IOPS, 3× lepší latence než Gen 6 |
|
|
||||||
|
|
||||||
**Klíčové vlastnosti**: podpora NVMe over FC, T10 DIF (Data Integrity Field), 10M MTBF, NIST SP 800-193 compliant. Gen 7 přináší až 10M IOPS a 3× nižší latenci oproti Gen 6.
|
|
||||||
|
|
||||||
### NVMe-oF specifikace
|
|
||||||
|
|
||||||
NVMe over Fabrics (NVMe-oF) rozšiřuje NVMe protokol z lokálního PCIe na síťové transporty. První specifikace 1.0 vydána v červnu 2016, aktuálně součástí NVMe 2.3 (srpen 2025). Podporované transporty:
|
|
||||||
|
|
||||||
| Transport | Specifikace | Use case |
|
|
||||||
|-----------|------------|----------|
|
|
||||||
| **NVMe over PCIe** | NVMe Base | Lokální NVMe SSD |
|
|
||||||
| **NVMe over RDMA** (RoCE, InfiniBand, iWARP) | NVMe Transport | AI/ML, HPC, nejnižší latence <5 µs |
|
|
||||||
| **NVMe over TCP** | NVMe Transport | Standardní Ethernet, bez RDMA, latence ~50 µs |
|
|
||||||
| **NVMe over FC** (FC-NVMe) | INCITS T11 | Enterprise SAN, FC fabric |
|
|
||||||
|
|
||||||
NVMe 2.3 přidává Computational Programs Command Set, Storage Level Management (SLM), a Zoned Namespaces (ZNS). NVMe-MI definuje management rozhraní.
|
|
||||||
|
|
||||||
### Dell PowerEdge R760 — NIC placement
|
|
||||||
|
|
||||||
Server Dell R760 podporuje:
|
|
||||||
- **OCP 3.0** adaptéry (až 2×) — 1/10/25/100 GbE
|
|
||||||
- **PCIe Gen5** sloty — 8× slotů (6× FHHL + 2× LP)
|
|
||||||
- **LOM** — 2× 1 GbE Broadcom 5720 na základní desce
|
|
||||||
- Maximální rychlost NIC: 100 GbE (QSFP56)
|
|
||||||
- Supported typy: RJ45, SFP+, SFP28, QSFP28, QSFP56
|
|
||||||
|
|
||||||
Doporučené konfigurace:
|
|
||||||
- Standard: OCP 3.0 2× 25 GbE + PCIe storage HBA
|
|
||||||
- AI/ML: PCIe 100 GbE (riser config 1, slot 1-2) + GPU v ostatních slotech
|
|
||||||
|
|
||||||
### HPE Gen11 NIC options
|
|
||||||
|
|
||||||
HPE ProLiant Gen11 (DL360/DL380) podporuje:
|
|
||||||
- **OCP 3.0** sloty (až 2) — 10/25/100/200 GbE (Broadcom, Intel, NVIDIA Mellanox)
|
|
||||||
- **PCIe Gen5** adaptéry — 8× slotů (DL380) / 3× sloty (DL360)
|
|
||||||
- **iLO 6** dedikovaný management port (1 GbE)
|
|
||||||
- Podporované NIC: Broadcom BCM57412 (10GbE), BCM57504 (25GbE), NVIDIA ConnectX-6 Dx (100GbE)
|
|
||||||
|
|
||||||
## Zdroje
|
|
||||||
|
|
||||||
Odkazy, knihy a standardy: [sources/infrastructure/sources.md](sources/infrastructure/sources.md)
|
|
||||||
|
|
||||||
### Doporučená literatura
|
|
||||||
|
|
||||||
| Kniha | Autoři | ISBN | Popis |
|
|
||||||
|-------|--------|------|-------|
|
|
||||||
| AI Data Center Network Design and Technologies (1st ed., 2026) | Subramaniam, Styszynski, Tambakuwala | 978-0-13-543628-8 | První vendor-agnostický průvodce návrhem sítí pro AI trénování a inferenci. Pokrývá high-radix fabric, lossless Ethernet/IP, UEC technologie, chlazení a power pro AI klastry. Autoři z HPE Juniper Networking. |
|
|
||||||
|
|
||||||
*Poslední revize: 2026-06-03*
|
|
||||||